| Property | Value |
|---|---|
| Flexural Strength | ≥180 MPa |
| Water Absorption | ≤25 µg/mm³ |
| Water Solubility | ≤2 µg/mm³ |
| Hardness | 1.0 ~ 1.2 GPa |
Tested for safety and biocompatibility – Honchon blocks are reliable for clinical dental applications.
| Test | Result |
|---|---|
| Cytotoxicity | Level 0 |
| Subchronic Systemic Toxicity | None |
| Skin Sensitization | None |
| Hemolysis | <5% |
| Ames Test | Mutation Negative |
| Oral Mucosal Irritation | None |
| Chromosome Aberration | None |
| TK Gene Mutation | None |